1, the measurement function: measuring positive and negative active, capacitive reactive power and round quadrant reactive energy;
2, time-measurement: with four rates, 12 time zones, divided into 10 days a day, a total of 4 sets of day time to choose from;
3, the monthly statistics of electricity: a total power and time sharing power and the total function of the previous day and last month's total electricity consumption measurement function;
4, the maximum demand: record the maximum demand and its emergence time, demand cycle default is 15 minutes, slip time default is 1 minute;
5, clock, calendar function (summer time 10 years automatic conversion)
6, power failure display (optional)
7, time recording function: record the occurrence time of a variety of events and the current state, such as phase failure, power failure, programming, reset, battery usage,
8, communication function: can use RS485 communication interface or infrared port, and handheld computers, computers or infrared remote control to communicate.
| 
				 Model and name  | 
			
				 Accuracy (level)  | 
			
				 Reference voltage (V)  | 
			
				 Calibration current (A)  | 
			
				 Wiring  | 
			
				 Packing size (mm)  | 
			
				 Quantity (only)  | 
		
| 
				 DTSD309 Three-phase four-wire multi-function Meter (Simple multi-function)  | 
			
				 1.0 2.0  | 
			
				 3×57.7/100 3×220/380  | 
			
				 1.5(6)  | 
			
				 Mutual inductance  | 
			
				 
					  | 
			
				 
					  | 
		
| 
				 5(20),10(40) 15(60),20(80),30(100)  | 
			
				 Direct type  | 
		|||||
| 
				 DTSD309 Three-phase four-wire multi-function Meter (Full Function)  | 
			
				 1.0 2.0  | 
			
				 3×57.7/100 3×220/380  | 
			
				 1.5(6)  | 
			
				 Mutual inductance  | 
		||
| 
				 5(20),10(40) 15(60),20(80),30(100)  | 
			
				 Direct type  | 
		|||||
| 
				 DTZ309 Three-phase four-wire charge control Smart energy meter  | 
			
				 1.0 2.0  | 
			
				 3×57.7/100 3×220/380  | 
			
				 1.5(6)  | 
			
				 Mutual inductance  | 
			
				 
					  | 
			
				 
					  | 
		
| 
				 5(20),10(40) 15(60),20(80),30(100)  | 
			
				 Direct type  | 
		
| 
					 standard  | 
				
					 Meet the JB / T7656-1995, DL / T614-1997 requirements  | 
			
| 
					 Pulse constant  | 
				
					 By nameplate standard  | 
			
| 
					 Reference frequency  | 
				
					 50HZ±5%  | 
			
| 
					 Clock error  | 
				
					 ≤0.5S/d  | 
			
| 
					 Mean time between failures (MTBF)  | 
				
					 ≥5×10?h  | 
			
| 
					 Power consumption  | 
				
					 <2W,10VA  | 
			
| 
					 Normal operating voltage  | 
				
					 (0.9~1.1)Vh  | 
			
| 
					 Limit operating voltage  | 
				
					 (0.7~1.2)Vh  | 
			
| 
					 Ambient temperature  | 
				
					 (-25~55)℃  | 
			
| 
					 Limit temperature  | 
				
					 (-25~70)℃  | 
			
| 
					 Relative humidity  | 
				
					 ≤75% (annual average temperature)  | 
			
| 
					 Design life  | 
				
					 15 years  | 
			
| 
					 Spare battery life  | 
				
					 10 years  | 
			
| 
					 Pulse output parameter  | 
				
					 Pulse width (80 ± 20) ms Voltage amplitude ≤ DC24V Passive  | 
			